Janitza
Home Page /Solar System/Energy Analyzer/Meter
Introducing Janitza
Janitza electronics GmbH, headquartered in Lahnau, Hessen, Germany, is a leader in energy measurement technology and power quality management. Since its founding in 1961, Janitza has provided comprehensive solutions for modern energy data management systems and residual current monitoring. Key products include integrated measurement devices, power quality analyzers, and power compensation systems. Janitza takes pride in developing and manufacturing all products in Germany, ensuring continuous quality and innovation.
- Product category: Meter
- Country of origin: Germany
- Website: https://www.janitza.com/
- Janitza – EXPERTS IN ENERGY MEASUREMENT TECHNOLOGY : Download
- All Drawing 2D & 3D of Product: Download
- Portable energy measurement devices: Download
Janitza Energy Measurement Devices
Transparency in energy management and measurement is crucial for modern businesses. Janitza’s energy measurement devices are the ideal choice for achieving this. With diverse communication interfaces and seamless integration capabilities, Janitza devices facilitate data collection and aggregation across all company departments. This optimizes production planning, enhances system safety, and reduces costs. Janitza products streamline complex network processes, integrating machine-level data with ERP systems and building management. By adopting the OPC UA data transmission standard, Janitza simplifies data aggregation, providing efficient and reliable solutions for modern business data management.
Janitza – Energy Meter
JANITZA
Creating transparency
The first step on the road to carbon neutrality is comprehensive transparency regarding carbon emissions. This includes systematically recording and analyzing consumption and the resulting emissions. The data obtained in this way forms the basis for all further measures and makes the success of the measures visible and verifiable.
Comprehensive Energy and Power Quality Management Solutions
With Janitza measurement technology, you benefit from a complete solution – from current transformers to measuring devices, analysis software to custom coding.
- Flexible and scalable system architecture
- Easy integration of non-communicating meters with digital inputs
- Capture all media, including water, air, gas, electricity, and steam (WAGES)
- Use your existing infrastructure or our adaptive system architecture
Easy Energy Monitoring
Products are manufactured using the latest production technology. At Janitza, quality management is a continuous business task. The company offers comprehensive expertise, authoritative consulting, and solution development to meet global customer needs and requirements
Janitza Equipped with the Most Modern Production Lines
Janitza’s new THT production line, operational since May 2018, features advanced technology combined with user-friendly functions. “THT” stands for “Through Hole Technology,” a semi-automatic component assembly system. It is one of the most modern production lines in Germany.
Research
Their services extend beyond measurement products and software; they also provide comprehensive consulting, maintenance support, and customer training. With German technical expertise and advanced in-house manufacturing capabilities, Janitza has become an internationally recognized provider of energy-saving systems.
PRODUCT LIST
MODEL NAME/MÃ SẢN PHẨM | DIMENSIONS / KÍCH THƯỚC (L*W*H) (mm) | AUX. SUPPLY | VOLTAGE MEASUREMENT INPUTS | CURRENT MEASURING INPUTS |
INTERFACE | PULSE OUTPUT | DOWNLOAD/ TẢI XUỐNG |
REQUEST FOR CONTACT/ YÊU CẦU LIÊN HỆ |
UMG 96-PQ-L | 96*96*87 | Option 230 V: AC 90 V – 277 V (50/60 Hz) or DC 90 V – 250 V, 300 V CATIII Option 24 V: AC 24 V – 90 V (50/60Hz) or DC 24 V – 90 V, 150 V CATIII |
417 V / 720 V (+-10%) according to IEC 347 V / 600 V (+-10%) according to UL |
1/5 A, 300 V CAT II | RS-485 – Modbus RTU/client device | 3 digital outputs, solid state relays, not short-circuit proof. | Download | Contact Us |
UMG 96-PQ-L-LP | 96*96*87 | Option 230 V: AC 90 V – 277 V (50/60 Hz) or DC 90 V – 250 V, 300 V CATIII Option 24 V: AC 24 V – 90 V (50/60Hz) or DC 24 V – 90 V, 150 V CATIII |
417 V / 720 V (+-10%) according to IEC 347 V / 600 V (+-10%) according to UL |
low-power current transformers or active rogowski coils | RS-485 – Modbus RTU/client device | 3 digital outputs, solid state relays, not short-circuit proof. | Download | Contact Us |
UMG 801 | 144*90*76 | DC: 24 V, PELV | 480 VLN / 830 VLL (+/-10%) according to IEC 347 VLN / 600 VLL (+/-10%) according to UL |
1/5 A, 300 V CAT II | RS-485 interface 3-conductor connection with A, B, GND |
4 digital outputs, solid state relays, not short-circuit proof | Download | Contact Us |
UMG 806 | 90*90*63.5 | AC/DC: 80 V – 270 V | 230 VLN / 400 VLL (+/-10 ) acc. IEC | 1/5 A, 300 V CAT II | RS485 interface x-wire connection |
Energy pulse output | Download | Contact Us |
UMG 804 | 158*108*59 | AC Power Supply: 90 .. 300 V AC (50-60 Hz) 24 V DC Power Supply: 12 .. 24 V DC |
480 VAC | 0 .. 600 A (external current transducer dependant) | RS485 interface x-wire connection |
2 | Download | Contact Us |
UMG 512-PRO | 144*144*75 | 95 V to 240 V (50/60 Hz) / DC 80 V to 300 V 48 V to 110 V (50/60 Hz) / DC 24 to 150 V |
417 V / 720 V (+10%) 347 V / 600 V (UL listed) |
1/5 A, 300 V CAT III 1/5 A, 300 V CAT II |
RS485 interface 3-wire connection with GND, A, B |
2 digital outputs with a joint earth; opto coupler, not short-circuit proof | Download | Contact Us |
UMG 509-PRO | 144*144*75 | 95 V to 240 V (50/60 Hz) / DC 80 V to 300 V 48 V to 110 V (50/60 Hz) or DC 24 to 150 V |
417 V / 720 V 347 V / 600 V UL listed |
1/5 A, 300 V CAT III 1/5 A, 300 V CAT II |
RS485 interface 3-wire connection with GND, A, B |
2 digital outputs with a joint earth; opto coupler, not short-circuit proof | Download | Contact Us |
UMG 96-PA | 96*96*87 | Option 230 V: AC 90 V – 277 V (50/60 Hz) or DC 90 V – 250 V, 300 V CATIII Option 24 V: AC 24 V – 90 V (50/60Hz) or DC 24 V – 90 V, 150 V CATIII |
417 V / 720 V (+-10%) according to IEC 347 V / 600 V (+-10%) according to UL |
1/5 A, 300 V CAT II | RS-485 – Modbus RTU/Slave | 3 digital outputs, solid state relays, not short-circuit proof. | Download | Contact Us |
UMG 96RM | 97*100*42 | 90V – 277V (50/60Hz) or DC 90V – 250V; 300V CATIII 24V – 90V AC / DC; 150V CATIII |
277 V/480 V (+-10%) | 1/5 A, 300 V CAT II | RS485 – Modbus RTU/slave | 2 digital outputs, semi-conductor relay, not short circuit protected | Download | Contact Us |
UMG 96RM-E | 97*100*42 | 90V – 277V (50/60Hz) or DC 90V – 250V; 300V CATIII 24V – 90V AC / DC; 150V CATIII |
277 V/480 V (+-10%) | 1/5 A, 300 V CAT II | RS485 – Modbus RTU/Slave | 2 and 3 optional digital outputs, semiconductor relays, not short-circuit proof. | Download | Contact Us |
UMG 96RM-CBM | 96*96*65 | 90V – 277V (50/60Hz) or DC 90V – 250V; 300V CATIII 24V – 90V AC / DC; 150V CATIII |
277 V/480 V (+-10%) | 1/5 A, 300 V CAT II | RS485 – Modbus RTU/slave | 6 digital outputs, semi-conductor relay, not short circuit protected. | Download | Contact Us |
UMG 96RM-PN | 96*96*57 | 90V – 277V (50/60Hz) or DC 90V – 250V; 300V CATIII 24V – 90V AC / DC; 150V CATIII |
277 V/480 V (+-10%) | 1/5 A, 300 V CAT II | RS485 to Modbus RTU/Slave | 2 and 3 optional additional digital outputs, semiconductor relay, not short-circuit proof | Download | Contact Us |
UMG 605-PRO | 90*107*82 | 95 V to 240 V (50/60 Hz) / DC 135 V to 340 V 50 V to 110 V (50/60 Hz) / DC 50 V to 155 V 20 V to 50 V (50/60 Hz) / DC 20 V to 70 V |
max. 277 V / 480 V | 1/5 A, 300 V CAT III | RS232 interface RS485 interface |
2 digital outputs; semiconductor relays, not short-circuit proof | Download | Contact Us |
UMG 604-PRO | 107*90*82 | 95 V to 240 V (50/60 Hz) / DC 135 V to 340 V 50 V to 110 V (50/60 Hz) / DC 50 V to 155 V 20 V to 50 V (50/60 Hz) / DC 20 V to 70 V |
max. 277 V / 480 V | 1/5 A, 300 V CAT III | RS232 interface RS485 interface |
2 digital outputs; semiconductor relays, not short-circuit proof | Download | Contact Us |
UMG 103-CBM | 71*90*46 | single phase: 115 – 277 V (+-10%), 50/60 Hz three phases: 80 – 277 V (+-10%), 50/60 Hz |
max. 277 V/480 V | 1/5 A, 300 V CAT II | RS485 interface | / | Download | Contact Us |